View real-time analogue values from loop devices to identify dirty sensors or failing hardware before they cause false alarms. Supported Hardware Protocols
: This is the "brain" of the operation. The software defines exactly what happens when a detector is triggered—for example, which sounders go off, which fire doors close, or if the elevators should be grounded. Network Management
After downloading a new configuration from Loop Explorer to the Kentec Syncro panel, a comprehensive cause-and-effect test must be conducted to verify that all output matrices trigger as designed.
One of the Syncro platform's greatest strengths is its scalability, and Loop Explorer is the key to unlocking it. The software is used to configure the optional . This card allows up to 64 Syncro panels to be connected in a high-integrity network, fully secure against short or open circuit faults. Kentec Syncro - Loop Explorer Software
LE-2 provides automatic update alerts, ensuring that the system is always running the latest version, which is critical for compliance and performance. D. Advanced Cause-and-Effect
Syncro panels can be networked together (up to 64 nodes) to create complex, site-wide fire protection systems.
(LE-2), which supersedes the original version. Key improvements include: Enhanced Security View real-time analogue values from loop devices to
Configuring a system from scratch involves defining your panel hardware, populating detection loops, and organizing devices into functional zones. Step 1: Creating a Project and Adding Nodes Open Loop Explorer and select . Right-click the Project Root and select Add Panel .
: A device is physically installed on the loop but is programmed as a different model inside the software.
I can provide step-by-step instructions to get your system configured correctly. Share public link This card allows up to 64 Syncro panels
A crucial function of the software is creating action types. For instance, an operator can select smoke detectors (input) from one loop, define a logic gate (like "OR"), and assign them to activate specific beacons (output) on another panel loop. Supporting Networked Systems
As he clicked through the intuitive interface, Elias began populating the loops. He added smoke detectors and heat sensors by double-clicking their icons, assigning each a unique 40-character address. He meticulously labeled them: "Suite 201 - Bedroom" and "Kitchen Heat Sensor" .
For each device, Loop Explorer displays:
VỀ NGUYÊN KHÔI
Bạn không thể sao chép nội dung của trang này!